ansorl addressable

Category:

Product Description

 FDAS Panel 2 To 16 Loops (AS9108E)

FDAS Panel 2 To 16 Loops (AS9108E)

•Available in 2 to 16 loops.
•7 inch color display LCD (800x480 Resolution)
•Operation and control are flexible and convenient through the standard USBinterfaced
•It adopts the non-polarity two-bus intelligent alarm linkage pattern and can connect 324 detectors
•System history logs upto 1000 pieces
•It can supports interconnection of 20 ANSORL9108E control units with CAN Bus and the maximum system capacity after networking reaches 16×324=5184

 FDAS Panel 1 Loop (MN3010)

FDAS Panel 1 Loop (MN3010)

•1 loop FACP
•4.3 inch color display LCD (430x272 res.)
•Operation and control are flexible and convenient through the standard USBinterfaced
•It adopts the non-polarity two-bus intelligent alarm linkage pattern and can connect 324 detectors
•System history logs upto 1000 pieces
•The maximum capacity of linkage control unit of a single equipment: 10 points.
•It supports interconnection of 20 MN3010 control units and the maximum system capacity after networking reaches 20×324=6480 (alarmpoint).

  Photo Electric Smoke Detectors(ASD102)

Photo Electric Smoke Detectors(ASD102)

•Built-in standalone CPU, quick calculating speed and excellent stability.
•Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring
•Built-in a standalone CPU which can process the sampling data in real-time.
•Three sensitivity levels of the detector are optional
•ESD static protection grade 12000V

  Rate of Rise Heat Detector (AHD105)

Rate of Rise Heat Detector (AHD105)

•Built-in standalone CPU, quick calculating speed and excellent stability.
•Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring.
•Sealed robber type of heat sensitivity
•Three sensitivity levels of the detector are optional
•Temperature rising compensation
• ESD static protection grade 12000V

  Combination Smoke and Heat Detector (ASH107)

Combination Smoke and Heat Detector (ASH107)

•Composite smoke-sensing and temperature-sensing detector is a multi-element composite detector constituted jointly by a smoke sensor and a semiconductor temperature sensor in respect of technological structure and circuit structure.
•Built-in standalone CPU, quick calculating speed and excellent stability.
•Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring.
•ESD static protection grade 12000V

 Combustible Gas Detector (AGD109)

Combustible Gas Detector (AGD109)

•Operating Volt: DC24V,
•Operating Current:Monitoring status, ≤ 35mA @DC24V; Alarm status, ≤ 40mA @DC24V.
•Two Bus system:Non polarity two-wire system, current < 400µA
•Operating environment: Temperature: 0℃~ 55℃; relative humidity: ≤95% (40℃±2℃, without condensation)

 Strobe Sounder Base (DZ102S)

Strobe Sounder Base (DZ102S)

•Operating voltage: DC24V ± 20%
•Quiescent current: ≤1mA; Alarm current: ≤130mA@DC24V
•Flushing rate: 1Hz~2Hz
•Alarm volume: 75dB~120dB
•Variable cycle: 4s-4.5s

 Manual Call Point (AMCP)

Manual Call Point (AMCP)

•Built-in standalone CPU, quick calculating speed and excellent stability.
•Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring.
•It has a built-in fire telephone jack and a PHONE indicator.
•ESD static protection grade 12000V, strong anti-interference ability.

 Strobe Sounder (AHS1)

Strobe Sounder (AHS1)

•Built-in standalone CPU, quick calculating speed and excellent stability
•Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring
•Sounder/ visual indicator setting freely according to different environment.
•With super bright red LED, it features markedness, long lifespan, and low

 Repeater Panel (ART)

Repeater Panel (ART)

•Built-in standalone CPU, quick calculating speed
•Connect the addressable panel by RS-485 bus, and each control panel can be with 99 units of fire display panels and KR-485 expansion cases, and each KR-485 expansion case can be with up to 50 fire display panel.
•It can give sound and light alarm signal, and support fault detecting and then warning by itself.

 Addressable Module

Addressable Module

•AIM INPUT MODULE
•AIO INPUT/OUTPUT MODULE
•AIS ISOLATOR MODULE